Restaurant and Bar Lighting Planner

For restaurant and bar owners, designers and contractors in Florida

Plan the lighting for your restaurant or bar

Enter the concept, the zones, the ceiling height, the daylight and the hours. Get light levels, layers, dimming scenes, color targets and an energy code check for each zone. Then copy the brief for your lighting designer.

ExampleA casual dining restaurant with a bar and a patio, in a tenant space. Change any value to plan your own.

Your restaurant

Concept
Floor area of each zone (sq ft)

Enter 0 for a zone you do not have.

The room

Reflectance in the math: light 80% ceiling and 50% walls, medium 50% and 30%, dark 10% and 10%.

Code and hours

Building
Project

Table C405.4.2(1). The code official confirms the zone.

Result

Zone plan

Each card shows the light target, the three layers of light, a fixture estimate, the code allowance, the controls and the color. All numbers are planning estimates.

Dimming scenes

A scene is a set of light levels that staff recall with one button. Each level is a share of full output. The light level changes in step with the share.

Scene levels for the dining room, bar and lounge (% of full output)

Service day

What the scenes need

    Energy code check

    The Florida Building Code, Energy Conservation, limits the lighting power in each space. This check compares the allowance with our estimate for the ambient layer. The rest of the allowance is left for accent and decorative light.

      Color for food and faces

      Two numbers describe white light. Color temperature (CCT, in kelvin) tells how warm or cool the light looks. The color rendering index (CRI) tells how true colors look under it (DOE).

      Project brief

      
              

      What happens next

      1. Copy the brief. Nothing leaves this page.
      2. Send it to your lighting designer with your floor plan.
      3. The designer checks the levels with a photometric plan.
      4. The designer quotes the fixtures, the controls and the lead times.

      Order early. Ask each supplier for the lead time of each fixture before you set the opening date.

      Questions owners and designers ask

      How bright should a dining room be?

      We found no Florida code light level for a dining room. We use the targets in UFC 3-530-01, the lighting criteria of the U.S. Department of Defense. They set 5 fc at the table in a dining room in housing (3-9.5.2) and 10 fc in an officer dining room (3-6.4.2). They set 15 fc in an enlisted dining room and in a cafeteria (3-6.3.2, 3-6.2.2). We use these values as planning ranges. Your lighting designer sets the final levels.

      What light levels does the health inspector check?

      Florida adopts the 2017 FDA Food Code (DBPR, Rule 61C-1.001). Section 6-303.11 of the Food Code sets these minimums:

      • 50 fc where staff work with food, or with knives, slicers and similar tools.
      • 20 fc at self-service counters and inside reach-in coolers.
      • 20 fc at 30 in above the floor at hand sinks, in dish areas and in toilet rooms.
      • 10 fc at 30 in above the floor in walk-in coolers and dry storage, and in other rooms during cleaning.

      Bulbs must be shielded or shatter-resistant where food is open (6-202.11).

      Does the energy code limit restaurant lighting?

      Yes. The Florida Building Code, Energy Conservation sets a lighting power allowance in watts per square foot. In the 8th Edition (Table C405.3.2(2)), family dining gets 0.60 and bar, lounge or leisure dining gets 0.86. Fast food dining gets 0.40, and food preparation areas get 1.09. The 9th Edition takes effect December 31, 2026 (ICC). It lowers the dining values and raises the food preparation and restroom values.

      Can we add pendants and chandeliers for their looks?

      Yes. With the Space-by-Space Method, decorative lighting can add up to 0.75 W per sq ft, or 0.9 in a lobby (C405.3.2.2.1). The decorative fixtures need their own control, apart from the general lighting (C405.2.5). The extra watts are only for those fixtures.

      Can we dim the dining room very low at night?

      Yes, but keep the exit path lit. While people are inside, the means of egress needs at least 1 fc at the walking surface (FBC 1008.2.1). Aisle accessways in Group A spaces are an exception (1008.2). If the room goes very dark, add step or aisle lights along the exit path.

      Which controls does the code ask for in a restaurant?

      The dining room, the bar and the kitchen need a time switch with a manual override of 2 hours or less (C405.2.2). They also need a way to dim or step down the light (C405.2.3). Restrooms and storage rooms need occupancy sensors (C405.2.1). Accent lights need their own control (C405.2.5). Outdoor lights must turn off in daylight (C405.2.7.1).

      Do we need daylight sensors near the windows?

      Spaces with more than 150 W of general lighting near windows or under skylights need daylight-responsive controls (C405.2.4). The floor area near windows on the first floor above grade of a Group A-2 space is an exception. Restaurants and bars are Group A-2 (FBC 303.3). With fewer than 50 people, a restaurant is Group B (303.1.1), and the exception does not apply.

      We only replace some fixtures. Does the code apply?

      In the 8th Edition, new lighting in a remodel must meet Section C405 (C503.5). The exception: you replace less than 10% of the fixtures in a space, and you do not add lighting power. Ask your designer how the 9th Edition treats remodels.

      Which white light makes food and faces look good?

      UFC 3-530-01 recommends 2700 K for hospitality spaces (2-1.4.6.1). Where color matters, it asks for CRI 90 or more with R9 of 50 or more (2-1.4.6.3). The DOE says R9, the saturated red sample, is very important for skin tones. Dim-to-warm fixtures usually give 2700 K to 3000 K at full output and get warmer as they dim.

      Why does the planner say "ask for a quote" for the budget?

      We found no public price list for restaurant lighting that we could check. The price depends on the fixtures, the controls and the labor. Send the brief to a lighting designer to get a quote with lead times.

      How the planner works

      1. Targets

      We take the light target of each zone from UFC 3-530-01 and the FDA Food Code. Full output is the top of the range. In guest spaces, full output is at least 10 fc, so the cleaning scene meets the Food Code.

      2. Fixtures

      We use the lumen method with one reference downlight: 2,245 lm, 30.5 W and a spacing criterion of 0.87 (Cooper report P295109). The coefficient of utilization comes from the report table. The light loss factor is 0.81 (UFC 3-2).

      3. Scenes

      Each scene is a share of full output. Lunch uses the top of the range and dinner the bottom. Late night starts at 30%, the low end of the UFC preset range. Cleaning uses 100%.

      4. Code

      We multiply the floor area of each zone by the allowance in Table C405.3.2(2) of the edition you pick. Then we compare the result with the ambient estimate.

      • The math treats each zone as a square room. Other room shapes change the count.
      • One ceiling height for all zones. One reference downlight for all indoor zones. Kitchens often use linear or panel fixtures.
      • We plan the whole kitchen at 50 fc. Storage and dish areas need less (10 fc and 20 fc).
      • We do not add daylight, accent, decorative or task light to the light level.
      • The exit path check divides the scene average by 3, the UFC average-to-minimum ratio. A photometric plan gives the real minimum.
      • No fixture count for the patio. Outdoor layouts depend on poles, string lights and covers.
      • No budget numbers. Ask for a quote.

      Sources

      We opened and read each source on the date shown. The code text belongs to its publishers. We give paraphrases and section numbers, not copies.

      1. 2023 Florida Building Code, Energy Conservation, 8th Edition (2021 IECC amended), Chapter 4 CE: Sections C401.2, C405.2, C405.3 and C405.4; Tables C405.3.2(1), C405.3.2(2), C405.4.2(1) and C405.4.2(2). ICC Digital Codes. https://codes.iccsafe.org/content/FLEC2023P1/chapter-4-ce-commercial-energy-efficiency. Read November 14, 2026.
      2. 2023 Florida Building Code, Energy Conservation, 8th Edition, Chapter 5 CE, Section C503.5 Lighting systems. ICC Digital Codes. https://codes.iccsafe.org/content/FLEC2023P1/chapter-5-ce-existing-buildings. Read November 14, 2026.
      3. 2026 Florida Building Code, Energy Conservation, 9th Edition (2024 IECC amended), Chapter 4 CE: Sections C405.2 and C405.3; Tables C405.3.2(1), C405.3.2(2) and C405.4.2(2). ICC Digital Codes. https://codes.iccsafe.org/content/FLEC2026V1.1/ce-chapter-4-commercial-energy-efficiency. Read November 14, 2026.
      4. Florida code list with effective dates (8th Edition: December 31, 2023; 9th Edition: December 31, 2026). ICC Digital Codes. https://codes.iccsafe.org/codes/united-states/florida. Read November 14, 2026.
      5. 2023 Florida Building Code, Building, 8th Edition, Chapter 10, Section 1008 Means of egress illumination. ICC Digital Codes. https://codes.iccsafe.org/content/FLBC2023P2/chapter-10-means-of-egress. Read November 14, 2026.
      6. 2023 Florida Building Code, Building, 8th Edition, Chapter 3, Sections 303.1.1 and 303.3 (Assembly Group A-2). ICC Digital Codes. https://codes.iccsafe.org/content/FLBC2023P2/chapter-3-use-and-occupancy-classification. Read November 14, 2026.
      7. UFC 3-530-01 Interior and Exterior Lighting Systems, 9 February 2023, Change 1 of 15 December 2023. U.S. Department of Defense, Unified Facilities Criteria (WBDG). https://www.wbdg.org/FFC/DOD/UFC/ufc_3_530_01_2023_c1.pdf. Read November 14, 2026.
      8. Food Code 2017, Section 6-202.11 Light bulbs, protective shielding, and Section 6-303.11 Intensity. U.S. Food and Drug Administration. https://www.fda.gov/media/110822/download. Read November 14, 2026.
      9. Hotels and Restaurants, Statutes and Rules: adopted editions of the FDA Food Code (2017 edition, effective November 1, 2019). Florida Department of Business and Professional Regulation. https://www2.myfloridalicense.com/hotels-restaurants/statutes-rules/. Read November 14, 2026.
      10. Rule 61C-1.001, Florida Administrative Code (reference material: 2017 FDA Food Code). Florida Department of State, FLRules. https://flrules.org/gateway/ruleNo.asp?id=61C-1.001. Read November 14, 2026.
      11. LED Color Characteristics, Solid-State Lighting Technology Fact Sheet, PNNL-SA-84900, January 2012. U.S. Department of Energy. https://www.energy.gov/sites/prod/files/2014/04/f14/led-color-characteristics-factsheet.pdf. Read November 14, 2026.
      12. Understanding LED Color-Tunable Products (last updated November 29, 2022). U.S. Department of Energy. https://www.energy.gov/eere/ssl/understanding-led-color-tunable-products. Read November 14, 2026.
      13. Photometric report P295109, Portfolio 6 in D2W downlight, medium distribution, LD6B30DE010 EU6B30509030D2W 6LBM0LI (issued March 3, 2020). Cooper Lighting Solutions. https://www.webtools.cooperlighting.com/Public/files/ies/instabase/PORTFOLIO/LED/6%20Inch%20Downlight%20-%20Version%20B/D2W/LD6B30DE010%20%20EU6B30509030D2W%206LBM0LI.pdf. Read November 14, 2026.
      14. Lighting control case study: Restaurant Daniel, New York (09/2000). Lutron Electronics. https://assets.lutron.com/a/documents/daniel_english.pdf. Read November 14, 2026.

      Ask a lighting designer about this project

      Send your plan to Holzer Lighting in Boca Raton, Florida. Holzer Lighting designs, specifies and buys lighting for owners, managers, designers and builders.

      A designer reads your brief and contacts you. The designer checks the rules, the light levels and the prices for your site. This page gives planning estimates only.

      You can also email info@holzerlighting.com or call 561.508.8990.