Court Light Planner

See the light on your court before you buy

Plan pickleball, tennis and padel court lights in a few minutes. Pick your courts and your level of play. Get the light levels, poles, fixtures, spill toward the neighbors, and a cost range, with a source for every rule.

Sport
Courts side by side
2
Level of play
20 ft
Poles
Nearest homes
60 ft
We use it only to show who can check your plan.

Your courts at night

Move over the map to read the light level
Light on the ground

Fixtures that fit this plan

We size each fixture for your courts and sort the list by fit and power use. Every number comes from the maker's spec sheet. Pick one to see it on the map.

Questions and answers

Short answers to common questions. Each answer links to its source.

How much light does a pickleball court need?

The planner uses the levels in LSI's pickleball lighting guide. The guide says the levels come from the ASBA construction and maintenance manual. Recreational play (Category III) calls for a 30 foot-candle (fc) average, with no point below 20 fc. Club play (Category II) calls for a 50 fc average, with no point below 40 fc. Professional play (Category I) calls for a 75 fc average, with no point below 60 fc. Evenness, the brightest point divided by the darkest point, should be 2.0:1 or less. For professional play, it should be 1.7:1 or less. These are maintained values over the playing area. The planner uses Categories III, II and I for its recreation, club and tournament levels.

How much light does a tennis court need?

The planner uses the USTA table in an NLS Lighting tennis brochure. Class IV, for high schools, clubs and parks, calls for a 30 fc average and a 20 fc minimum. Class III, for clubs, homes and parks, calls for a 50 fc average and a 40 fc minimum. Class II, for college matches, clubs and homes, calls for a 75 fc average and a 60 fc minimum. Class I, for broadcast television, calls for a 125 fc average. The planner uses Classes IV, III and II for its recreation, club and tournament levels. The table also says that older players need more light.

How tall should the court light poles be?

Pole height sets how steeply each fixture can aim. The Texas Amateur Athletic Federation (TAAF) lighting standards ask tennis fixtures to aim at least 25 degrees below horizontal. That is 65 degrees or less from straight down, the limit in the planner's steepest aim tile. TAAF also says to put poles outside the fences where possible. For tennis, it advises against a 6-pole layout with poles at the net line. A pole there can sit in the server's sight line. An NLS tennis brochure calls 18 to 22 ft the most common mounting heights. Check your local code for a height limit.

How do we keep light out of the neighbors' yards?

Local codes can limit the light that crosses the property line. The Joint IDA-IES Model Lighting Ordinance (2011) is a model that towns can adopt. It treats open courts as lighting by special permit, with controls that cut the light at a curfew. It also limits light at the property line by lighting zone. Zone 2, which includes neighborhood playing fields, allows 0.3 fc. The planner checks the light 5 ft above the ground at your nearest homes against that limit.

For example, unincorporated Palm Beach County allows 0.33 fc at a home's property line, measured 6 ft above grade (ULDC Art. 5.E.4.E). There, outdoor recreation lights go off at 11:00 p.m., except to finish a scheduled event that began before then. Single-family lots there are exempt from these limits. Their lights must still aim away from neighbors and streets.

What should we look for in LED court lights?

Compare fixtures by the lumens and watts on each maker's spec sheet. The planner sorts the fixtures that fit by power use. Ask each maker for the IES file and a photometric layout of your courts. If homes are near, look for a fixture with a visor or shield. The planner assumes that such a fixture sends no light above 75 degrees from straight down.

To run practice at a lower level, add a dual control, as the Model Lighting Ordinance suggests. If you replace metal halide lights, expect them to have lost light. A Penn State study measured 37 sports fields with 1,500 W metal halide lamps. It found a light loss factor of 0.75 at 1,200 hours and 0.65 at 3,000 hours. The planner uses a factor of 0.85 for its LED fixtures.

Can we reuse our tennis court poles for pickleball?

LSI's conversion guide shows layouts that keep a tennis court's poles and put new LED fixtures on them. It shows one, two and four pickleball courts on one tennis court. The guide also says most tennis courts use 6 or 8 poles with 1 or 2 fixtures on each. The planner's light map uses its own pole layout. A photometric study of your real pole positions, with the maker's IES file, confirms the result.

Do we need a permit to light a court?

The Florida Building Code, Sec. 105.1, says an owner must get a permit before installing or changing an electrical system that the code regulates. New court lights add wiring, poles and bases. Apply to your city or county building department before you order. Some places also ask for a sealed photometric plan. For example, unincorporated Palm Beach County asks for one with each building permit application for outdoor lights, except on single-family lots (ULDC Art. 5.E.4.E). If you are in an HOA, check its rules too.

Our courts are near the beach. What about sea turtles?

Florida's model sea turtle lighting ordinance (Rule 62B-55.004, F.A.C.) covers new and existing lights that are visible from the beach. It names public parks and recreational areas. In the model, lights for outdoor areas must be long wavelength (560 nanometers or more), aimed down, full cutoff and fully shielded. They must also sit as close to the ground as possible. Local governments adopt their own ordinances, and FWC keeps a list. In the model's guidance, nesting season in Palm Beach and Broward counties runs March 1 to October 31. In Miami-Dade, it runs May 1 to October 31. Ask the maker if a court fixture meets your local rule.

Your plan


        

How it works

1. Target

We take the average light level and the evenness for your sport and level of play from published guidance (table below).

2. Layout

Poles stand on the fence lines between courts, so neighbors share poles. Each pole lights the courts on both sides.

3. Light map

We add the light from every fixture at points 2 ft apart, using the maker's lumens and beam spread, and a light loss factor for aging and dirt.

4. Check

We raise the fixture count until the average meets the target, then choose the aiming with the most even light. A photometric study with the maker's IES file confirms the final design.

Owner notes

    Ask a lighting designer about this project

    Send your plan to Holzer Lighting in Boca Raton, Florida. Holzer Lighting designs, specifies and buys lighting for owners, managers, designers and builders.

    A designer reads your brief and contacts you. The designer checks the rules, the light levels and the prices for your site. This page gives planning estimates only.

    You can also email info@holzerlighting.com or call 561.508.8990.

    About Holzer Lighting

    Other free lighting tools:

    Holzer Lighting gets your details and the project brief from this page. They use them only to answer you.