Condo Light Savings

What LED lighting saves in your common areas

Count the fixtures in the garage, hallways, stairwells, lobby, walkways and pool deck. See the yearly power and lamp costs before and after LED, the payback, and a summary for your board.

Building type
Fixtures by area
We use it only to show who can check your plan.

Your building in section

Each common area is shaded by its yearly savings.
Cross-section of the condo building with the garage, lobby, hallways, stairwells, walkways and pool deck shaded by yearly savings.
Yearly savings per area

    Before and after, by area

    TodayAfter LED

    Savings by area

    Yearly values at your hours and power rate. Lamp changes count the lamp price and the labor for each change. LED fixtures need no lamp changes in the payback period.

    The numbers we use

    Change any value to match your building or a contractor quote. Watts come from a utility table of standard fixture watts and from maker spec sheets. Installed LED costs are estimates.

    Sensors and the Florida code

    Questions and answers

    Each answer gives the code, law or study that it uses. Codes and rates change, so check the source before the board votes.

    Where does LED lighting save the most in a condo?

    In the areas that stay lit the longest. The building code requires light on the exit path at all times that the space is occupied (FBC Building 1008.2). For this reason, this page uses 24 hours a day for garages, hallways and stairwells. Old fixtures also use power in the ballast. For example, a fixture with one 150 W high pressure sodium lamp uses about 188 W in total (PG&E fixture watt table). In a U.S. Department of Energy study of a federal office garage, LED fixtures used 52 percent less energy than the old sodium fixtures. With motion sensors, the saving rose to 88 percent (DOE report PNNL-22388, 2013). Your building will give different results.

    Can motion sensors dim the hallway and stairwell lights?

    Yes, within limits. The exit path needs at least 1 footcandle (fc) at the walking surface at all times that the space is occupied. Exit stairways and their landings need 10 fc when people use them (FBC Building 1008.2.1). So a sensor can dim an empty stairway, but the low level must still give 1 fc. The energy code calls them occupant sensors. It allows sensors that turn the lights fully on by themselves in corridors, garages and stairways (FBC Energy C405.2.1.1). Corridor sensors must lower the power to 50 percent or less within 20 minutes after people leave (C405.2.1.4).

    Do condo garage lights need motion sensors?

    New garage lighting needs a motion sensor or a time switch (FBC Energy C405.2.8). Each fixture must also lower its power by at least 30 percent after 20 minutes with no activity. Each control zone can be up to 3,600 sq ft. A zone with less than 1.5 fc at its darkest point, with all lights on, does not need this step. These rules apply to new buildings and to new lighting systems in an alteration. The next question tells when an alteration counts.

    Does the energy code apply when we replace our old fixtures?

    It can. New lighting systems in an alteration must meet Sections C405 and C408 (FBC Energy C503.5). This does not apply if you replace less than 10 percent of the fixtures in a space and do not add lighting power. C405 is in the commercial part of the energy code. A building with more than two dwelling units, where most people live full time, is in Group R-2 (FBC Building 310.4). Under the energy code, an R-2 building of three stories or less is a residential building, not a commercial building (FBC Energy C202). Ask a lighting designer or your building official what applies to your building.

    How does this page work out the payback?

    Simple payback is the project cost divided by the yearly savings. The savings have three parts: less energy, a lower demand charge on a demand rate, and fewer lamp changes. Energy and demand prices come from the FPL business rates effective January 2026 (FPL business rates). The page does not count rate increases, taxes, fees or utility programs. Project costs are estimates, so the page shows a range. Put a contractor quote in the table of numbers above to see your own payback.

    Will an LED project change our emergency lights?

    It can, so plan for it. Emergency power for the exit path comes from batteries, unit equipment or a generator. It must last at least 90 minutes (FBC Building 1008.3.4). At the start, emergency lights must give an average of at least 1 fc on the exit path (1008.3.5). The darkest point must get at least 0.1 fc. If the old fixtures do this job, the new fixtures must do it too. Test the emergency lights after the work. Ask your fire inspector about the test rules.

    Can we pay for the LED project from our reserves?

    A Florida condo budget must have reserve accounts for roof replacement, building painting and pavement resurfacing. It must also have reserves for any other item with a deferred maintenance expense or replacement cost over $25,000. If the state division sets a higher amount for inflation, the higher amount applies (s. 718.112(2)(f)2.a., F.S.). Using reserve funds for another purpose needs a majority vote of all the voting interests first (s. 718.112(2)(f)3.). More limits apply to buildings that need a structural integrity reserve study. Ask your manager and your reserve study provider before you plan the funding.

    What do we do with the old fluorescent and HID lamps?

    Plan to recycle them. Fluorescent lamps of all types and HID lamps, such as metal halide and high pressure sodium, contain mercury (Florida DEP). Florida law does not let anyone knowingly burn spent mercury lamps in an incinerator. The law also covers commercial and institutional facilities that dispose of more than 10 spent lamps a month. They must use a permitted lined landfill or a permitted reclamation (recycling) facility (s. 403.7186, F.S.). Ask your contractor for a recycling receipt. The costs on this page do not include lamp disposal.

    Board summary and next step

    Summary for the board

    
            

    Send to a lighting pro

    Copy this project brief and send it with your inquiry. A lighting pro checks the light levels, the code rules and the costs.

    
            

    How it works

    1. Power before

    Each old fixture uses its full input watts, lamp plus ballast, from a utility table of standard fixture watts. We multiply by the count and the hours each day, for 365 days.

    2. Power after

    Each LED fixture uses the input watts on the maker's spec sheet. Motion sensors lower the power when an area is empty, at the low level you choose.

    3. Dollars

    We apply the FPL energy and clause charges. On a demand rate, lower watts in areas lit during the day also lower the monthly demand charge.

    4. Lamp changes

    Old lamps fail after their rated life. Each change costs the lamp price plus labor. Payback is the project cost divided by the yearly savings.

    Sources

      Notes for the owner

      Built on November 7, 2026. Not deployed. There is no repo yet. Run the repo-setup skill before any deploy. The name "Condo Light Savings" is not checked yet (run the ht-name-check skill).

      Sources (all opened on November 6 to 7, 2026)

      Our assumptions

      • Hours. Garage, hallways, stairwells: 24 hours (FBC Building 1008.2). Lobby: 24 hours. Exterior walkways and pool deck: 12 hours, dusk to dawn. Garden-style breezeways and open stairs: 12 hours on a photocell.
      • Sensor time at full light. Garage 30% of hours (DOE PNNL-22388 measured 17% at a 2.5 minute delay and 47% at 10 minutes; the VCPG uses 5 minutes). Hallways 35%. Stairwells 10%. These are our values, not measured in condos.
      • Sensor low levels. Garage 37% (VCPG PIR spec). Hallways 50% (the code maximum in C405.2.1.4). Stairwells 50% (WL4 DIM50); 10% (DIM10) is offered with a warning chip.
      • Demand charge. On GSD-1, areas lit 13 hours or more a day lower the billed demand by their watt drop. Night-only areas do not. Sensor dimming does not count toward demand. Default rate: GSD-1 for high-rise and mid-rise, GS-1 for garden style. The GS-1 and GSD-1 kW limits are not confirmed from the FPL tariff.
      • Lamp changes. Labor at $80 an hour. 15 minutes per change for interior lamps (DOE PNNL-22388 uses about 15 minutes). 30 minutes for wall packs and garage lamps. Ballast failures are not counted, so the old-fixture cost is low.
      • LED costs (estimates). Installed cost per fixture: T8 to LED fixture $175 to $325; CFL downlight to LED $125 to $250; metal halide wall pack to LED $425 to $650 (includes the public $327.60 WPX2 price); HPS garage to LED $375 to $600; halogen PAR38 to LED lamp $20 to $40 (includes the public $14.50 lamp price). Motion sensor $50 to $100 more. The page uses the midpoint and shows the range.
      • LED upkeep. No upkeep for LED fixtures in the payback period. LED PAR38 lamps are replaced at their 50,000 hour rated life.
      • LED sizes. We pick sizes with a light output close to the old fixture: WPX2 (47 W) and not the WPX1 P2 (24 W) that the maker says can replace up to 175 W metal halide; VCPG P4 (56 W) and not P3 (43 W).
      • Examples. The fixture counts for each building type are invented examples. The page labels them "Example".

      To confirm before launch

      • The LED model and size for each old fixture type, and the light levels they give.
      • The stairwell low level. A 10% level is allowed only if the stair keeps 1 footcandle at the walking surface (FBC Building 1008.2.1).
      • Whether a fixture-for-fixture LED swap is a "new lighting system" under FBC Energy C503.5. If yes, corridor sensors (C405.2.1) and garage dimming (C405.2.8) apply to buildings of four or more stories. A condo of three stories or less is a residential building (C202), so the page shows the residential note for the garden-style example.
      • The Florida Fire Prevention Code (NFPA 101) rules for motion sensors in the means of egress. We did not open NFPA 101, because the free view needs a sign-in.
      • The installed cost ranges, the $80 labor rate, and the sensor full-light times.
      • Which FPL rate class condo common meters usually have (GS-1 or GSD-1).
      • Lobby hours (24) and pool deck hours (12).

      Engine limits

      • Simple payback only. No rate increases, no discount rate, no taxes or franchise fees, no utility programs.
      • The demand charge model is rough. The real billed demand depends on when the monthly peak happens.
      • No light level calculation. The LED picks match the old light output only roughly.
      • One LED product for each old type. Real projects mix sizes and makers.
      • Old fixture watts come from a 2005 utility table. Real watts change with the ballast.
      • The page uses the 8th Edition Florida Building Code. The 9th Edition starts on December 31, 2026. Recheck the section numbers then.
      • Lamp disposal (fluorescent and HID lamps contain mercury) and ballast changes are not in the costs.

      Routing plan

      The county select changes only the routing text. Palm Beach, Broward and Miami-Dade projects go to the Lighting Certified (LC) designer. Other areas go to a partner. No partner is signed. The page has no form and no backend. The project brief is copy only. There are no referral or affiliate tags.

      Ask a lighting designer about this project

      Send your plan to Holzer Lighting in Boca Raton, Florida. Holzer Lighting designs, specifies and buys lighting for owners, managers, designers and builders.

      A designer reads your brief and contacts you. The designer checks the rules, the light levels and the prices for your site. This page gives planning estimates only.

      You can also email info@holzerlighting.com or call 561.508.8990.

      About Holzer Lighting

      Other free lighting tools:

      Holzer Lighting gets your details and the project brief from this page. They use them only to answer you.